AAS Flame Furance
  • AAS Flame Furance Manufacturers, AAS Flame Furance Factory, Wholesale AAS Flame Furance

AAS Flame Furance

Brand KN

Product origin Dalian,China

Delivery time deliver as soon as received payment

Supply capacity 30 sets per month

When fuels are combusted, metals present in the fuels can form low melting compounds that are corrosive to metal parts. Metals present at trace levels in petroleum can deactivate
catalysts during processing. These test methods provide a
means of quantitatively determining the concentrations of vanadium, nickel, iron, and sodium. Thus, these test methods can be used to aid in determining the quality and value of the crude oil and residual oil.

AAS Flame Furance

KN-AAS Flame Furnace Atomic Absorption Spectrophotometer

Overview

KN-AAS Flame Furnace Atomic Absorption Spectrophotometer conforms to ASTM D5863 Standard Test Methods for Determination of Nickel, Vanadium, Iron, and Sodium in Crude Oils and Residual Fuels by Flame Atomic Absorption Spectrometry. When fuels are combusted, metals present in the fuels can form low melting compounds that are corrosive to metal parts. Metals present at trace levels in petroleum can deactivate catalysts during processing. These test methods provide a means of quantitatively determining the concentrations of vanadium, nickel, iron, and sodium. Thus, these test methods can be used to aid in determining the quality and value of the crude oil and residual oil.

 

Features

  1. High precision automatic optical system

  2. Polymer spray chamber, Polymer materials corrosion spray chamber, acid and alkali resistance

  3. Titanium burner, the optional 50mm and 100mm burner

  4. Automatic analysis, It can automatically accomplish safety ignition, extinction and switching, Reliable structure, low fault rate, thus ensuring the sensitivity and reproducibility of the flame method. He light source system six lamp automatic conversion, can be directly used high performance hollow cathode lamp, improve the sensitivity analysis of the flame, the automatic adjustment of the power supply parameters and the beam position, automatic wavelength scanning and searching peak


Technical parameters

 Mainframe

  • Light Source: ≤3 lamps automatic turret, automatic alignment

  • Power Supply: 110/220V (+5% ~ -10%), 60/50Hz; 5000VA

  • Lamp Current: pulsed power supply

  • Optical System: large 1800 /mm grating ruling, full closed optical system

  • Wavelength Range: 190nm-900nm , Automatically peak find, a key optical optimization function

  • Wavelength Accuracy:≤0.15nm

  • Wavelength Repeatability:±0.1nm

  • Spectral Bandwidth: 0.1nm、0.2nm、0.4nm、1.0nm、2.0nm,(5 steps with automatic changeover)

  • Baseline Stability:≤±0.002A/30 min (Static), ≤±0.005A/30min (Dynamic)

  • Absorbance Range: 0-4A


Flame Analytical System

  • Detector: imported photomultiplier tube

  • Burner Head: full titanium combustion head, 50mm or 100mm general combustion head

  • Atomization Chamber: polymer explosion-proof spray chamber

  • Nebulizer : atomizer efficient glass atomizer, can also be customized

  • Ignition Type: microcomputer control, automatic ignition

  • Gas Control: automatic gas control system

  • Detection Limits(Cu): 0.002μg/mL

  • Precision: RSD≤0.5%