AAS Flame Furance
Brand KN
Product origin Dalian,China
Delivery time deliver as soon as received payment
Supply capacity 30 sets per month
When fuels are combusted, metals present in the fuels can form low melting compounds that are corrosive to metal parts. Metals present at trace levels in petroleum can deactivate
catalysts during processing. These test methods provide a
means of quantitatively determining the concentrations of vanadium, nickel, iron, and sodium. Thus, these test methods can be used to aid in determining the quality and value of the crude oil and residual oil.
KN-AAS Flame Furnace Atomic Absorption Spectrophotometer
Overview
KN-AAS Flame Furnace Atomic Absorption Spectrophotometer conforms to ASTM D5863 Standard Test Methods for Determination of Nickel, Vanadium, Iron, and Sodium in Crude Oils and Residual Fuels by Flame Atomic Absorption Spectrometry. When fuels are combusted, metals present in the fuels can form low melting compounds that are corrosive to metal parts. Metals present at trace levels in petroleum can deactivate catalysts during processing. These test methods provide a means of quantitatively determining the concentrations of vanadium, nickel, iron, and sodium. Thus, these test methods can be used to aid in determining the quality and value of the crude oil and residual oil.
Features
High precision automatic optical system
Polymer spray chamber, Polymer materials corrosion spray chamber, acid and alkali resistance
Titanium burner, the optional 50mm and 100mm burner
Automatic analysis, It can automatically accomplish safety ignition, extinction and switching, Reliable structure, low fault rate, thus ensuring the sensitivity and reproducibility of the flame method. He light source system six lamp automatic conversion, can be directly used high performance hollow cathode lamp, improve the sensitivity analysis of the flame, the automatic adjustment of the power supply parameters and the beam position, automatic wavelength scanning and searching peak
Technical parameters
Mainframe
Light Source: ≤3 lamps automatic turret, automatic alignment
Power Supply: 110/220V (+5% ~ -10%), 60/50Hz; 5000VA
Lamp Current: pulsed power supply
Optical System: large 1800 /mm grating ruling, full closed optical system
Wavelength Range: 190nm-900nm , Automatically peak find, a key optical optimization function
Wavelength Accuracy:≤0.15nm
Wavelength Repeatability:±0.1nm
Spectral Bandwidth: 0.1nm、0.2nm、0.4nm、1.0nm、2.0nm,(5 steps with automatic changeover)
Baseline Stability:≤±0.002A/30 min (Static), ≤±0.005A/30min (Dynamic)
Absorbance Range: 0-4A
Flame Analytical System
Detector: imported photomultiplier tube
Burner Head: full titanium combustion head, 50mm or 100mm general combustion head
Atomization Chamber: polymer explosion-proof spray chamber
Nebulizer : atomizer efficient glass atomizer, can also be customized
Ignition Type: microcomputer control, automatic ignition
Gas Control: automatic gas control system
Detection Limits(Cu): 0.002μg/mL
Precision: RSD≤0.5%