Apparatus for Sulfur Content in Petroleum Products
  • Apparatus for Sulfur Content in Petroleum Products Manufacturers, Apparatus for Sulfur Content in Petroleum Products Factory, Wholesale Apparatus for Sulfur Content in Petroleum Products

Apparatus for Sulfur Content in Petroleum Products

Brand KN

Product origin DALIAN

Delivery time 30 DAYS AFTER RECEIVING FULL PAYMENT

Supply capacity 30 sets/month

KN-7039 Apparatus for Sulfur Content in Petroleum Products by WDXRF conforms to ASTM D7039 Standard Test Method for Sulfur in Gasoline, Diesel Fuel, Jet Fuel, Kerosine, Biodiesel, Biodiesel Blends, and Gasoline-Ethanol Blends by Monochromatic Wavelength Dispersive X-ray Fluorescence Spectrometry. & ASTM D2622 Standard Test Method for Sulfur in Petroleum Products by Wavelength Dispersive X-ray Fluorescence Spectrometry. The sample is placed in the X-ray beam, and the peak intensity of the sulfur Kα line at 0.5373 nm is measured. The background intensity, measured at a recommended wavelength of 0.5190nm (0.5437nm for a Rh target tube) is subtracted from the peak intensity. The resultant net counting rate is then compared to a previously prepared calibration curve or equation to obtain the concentration of sulfur in mg/kg or mass %.

Apparatus for Sulfur Content in Petroleum Products

KN-7039 Apparatus for Sulfur Content in Petroleum Products

Overview

  KN-7039 Apparatus for Sulfur Content in Petroleum Products by WDXRF conforms to ASTM D7039 Standard Test Method for Sulfur in Gasoline, Diesel Fuel, Jet Fuel, Kerosine, Biodiesel, Biodiesel Blends, and Gasoline-Ethanol Blends by Monochromatic Wavelength Dispersive X-ray Fluorescence Spectrometry. & ASTM D2622 Standard Test Method for Sulfur in Petroleum Products by Wavelength Dispersive X-ray Fluorescence Spectrometry. The sample is placed in the X-ray beam, and the peak intensity of the sulfur Kα line at 0.5373 nm is measured. The background intensity, measured at a recommended wavelength of 0.5190nm (0.5437nm for a Rh target tube) is subtracted from the peak intensity. The resultant net counting rate is then compared to a previously prepared calibration curve or equation to obtain the concentration of sulfur in mg/kg or mass %.

 

Features

1. Johansson-type DCG system, advanced design of beam path

2. After calibration before ex-factory, will never have optical path displacement

3. No need conversion gasses, vacuum requirements or self-aeration system

4. No need to establish working curves frequently

5. Intuitive touch screen operation

 

Technical parameters

1. Limit of detection 0.2ppm (300s)

2. Range: 0.5ppm~5%

3. Measuring time: 60~300s (selectable)

4. Standard deviation: Sn-1≤0.5ppm (5ppm), 2.5ppm (50ppm)

5. I/O ports: USB

6. Rated voltage: 220V±10%, 5A/110V±10%, 5A

7. Dimension: 614*444*375mm