ASTM D5453 Ultraviolet Fluorescence Sulfur Content
  • ASTM D5453 Ultraviolet Fluorescence Sulfur Content Manufacturers, ASTM D5453 Ultraviolet Fluorescence Sulfur Content Factory, Wholesale ASTM D5453 Ultraviolet Fluorescence Sulfur Content

ASTM D5453 Ultraviolet Fluorescence Sulfur Content

Brand KN

Product origin Dalian,China

Delivery time deliver as soon as received payment

Supply capacity 30 sets one month

Some process catalysts used in petroleum and chemical refining can be poisoned when trace amounts of sulfur bearing materials are contained in the feedstocks. This test method can be used to determine sulfur in process feeds sulfur in finished products, and can also be used for purposes of regulatory control.

ASTM D5453 Ultraviolet Fluorescence Sulfur Content

KN-5453 Ultraviolet Fluorescence Sulfur Tester

Overview

KN-5453 Ultraviolet Fluorescence Sulfur Tester adopts advanced total sulfur analysis method--ultraviolet fluorescence method, determine the total sulfur content of various kinds of gas, liquid, solid oils and chemical product. It is a apparatus with high sensitivity, stable property, low detection lower limit, accurate test result, good repeatability. The apparatus conforms to the ASTM D5453.

 

Feature

  1. We adopts the most advanced ultraviolet lamp and other critical components to ensure the super high sensitivity and reliability.

  2. Adopts the imported American Nafion pipe membrane dryer, good water removal to ensure the stability apparatus

  3. The apparatus can establish and store the working curve, user can make the specimen analysis without establishing the working curve again.

  4. By selecting the gas smple injector or the solid sample injector, the apparatus can make the analysis of gas, liquid and solid sample to meet various tests

  5. Windows interface, convenient to operate

 

Technical Parameters

  1. Specimen species: liquid, solid and gas specimen

  2. Measurement method: ultraviolet fluorescence

  3. Specimen sample size: solid sample size: 1~20mg

  4. liquid sample size: 1~30μL

  5. gas sample size: 1~10 mL

  6. Measurement range: 0.2 mg/L~3%

  7. Detection lower limit: 0.2 mg/L

  8. Temperature control range: room temperature to 1100℃

  9. Temperature control precision: 0.5%±2℃

  10. Gas source requirement: argon: above 99.995% ,oxygen: above 99.99%, humidity<5%

  11. Rated voltage: AC220V±22V 50Hz±0.5Hz

  12. Power: 1500W

Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy