ASTM D7419 HPLC for Total Aromatics and Total Saturates
Brand KN
Product origin DALIAN
Delivery time 30 DAYS AFTER RECEIVING FULL PAYMENT
Supply capacity 30 sets/month
KN-7419 HPLC for Total Aromatics and Total Saturates conforms to ASTM D7419 Standard Test Method for Determination of Total Aromatics and Total Saturates in Lube Basestocks by High Performance Liquid Chromatography (HPLC) with Refractive Index Detection. The composition of a lubricating oil has a large effect on the characteristics and uses of the oil. The determination of saturates, aromatics and polars is a key analysis of this composition. The characterization of the composition of lubricating oils is important in determining their interchangeability for use in blending etcetera.
KN-7419 HPLC for Total Aromatics and Total Saturates
Overview
KN-7419 HPLC for Total Aromatics and Total Saturates conforms to ASTM D7419 Standard Test Method for Determination of Total Aromatics and Total Saturates in Lube Basestocks by High Performance Liquid Chromatography (HPLC) with Refractive Index Detection. The composition of a lubricating oil has a large effect on the characteristics and uses of the oil. The determination of saturates, aromatics and polars is a key analysis of this composition. The characterization of the composition of lubricating oils is important in determining their interchangeability for use in blending etcetera.
Features:
The static motor control circuit designed with independent technology realizes the automatic feedback tracking function of the motor control signal, effectively improves the motor control accuracy, and ensures the reliability and stability of the pump
The technology of floating self-calibrating sealing ring technology and pump head self-cleaning function can prolong the service life of the sealing ring and ensure the durability and high efficiency of the tester
Easy-to-use flow and pressure calibration functions ensure the high precision and stability of the tester
Program design with two gradients: linear gradient and step gradient optional
Programmable solvent classes and compression factors that automatically compensate for complete pre-cleaning for quick solvent changes.
Optional automatic cleaning plunger and sealing ring device
There are three modes: single wavelength test, time-wavelength program test and wavelength scanning test
OLED graphic display screen, with the functions of automatically lighting the deuterium lamp, wavelength self-calibration, and automatic zero adjustment after the power-on self-test is completed
Adopts a double beam monochromator optical system centered on a concave grating and a transmission device powered by a microprocessor-controlled stepping motor to ensure the accuracy and reproducibility of the wavelength
Technical parameters:
Pump type: Double plunger tandem reciprocating pump
Flow rate range: 0.001~10ml/min (set step size 0.001ml/min)
Flow rate accuracy≤±0.1% (0.001~10ml/min)
Max working pressure: 50MPa, be able to set upper and lower limit, automatic alarm
Pressure display error<±0.5Mpa (0~50MPa)
Pressure pulsation<0.1MPa
Pump leakproofness: When 42MPa, pressure decrease<0.5MPa within 10min
Flow rate precision: RSD<0.05%
Gradient: Binary or quaternary
Programmable flow control function
Flow rate regulation steps: 20
Program time: Max 6000min
File capacity: 20
Dual pump control high pressure gradient function
Gradient type: Horizontal Ladder and Function (Linear)
Max program steps: 20
Mixing ratio setting range: 0~100% (Increment 0.1%)
Gradient error: ±1.5% [acetone/water solution, (0~100)%, flow 1.0mL/min, (1.0~20)MPa, detector wavelength 254nm]
Gradient file capacity: 20
Technical characteristics
Temperature setting range: Ambient~80℃
Temperature display resolution: 0.1℃
Temperature control accuracy:±1℃
Overheating protection:80℃
Heating power: 100W
Wavelength range: 190~700nm wavelength scanning
Wavelength accuracy: ±1nm
Wavelength repeatability: ±0.1nm
Wavelength bandwidth: 8nm
Flow cell volume: 8ul
Baseline noise: ±0.15×10-5AU (wavelength is 254nm, air in the flow cell)
Baseline drift: 1×10-4AU/h (wavelength is 254nm, air in the flow cell)
Standard configuration
No. | Item | Quantity |
1 | Dedicated software | 1 set |
2 | UV detector (wavelength range: 190-700nm) | 1 set |
3 | High pressure infusion pump (analytical type) | 2 sets |
4 | High pressure mixer (analytical) | 1 piece |
5 | Manual injection valve | 1 set |
6 | 4.6*250 Chromatographic column | 1 piece |
7 | Injection valve support | 1 piece |
8 | Vacuum pump | 1 set |
9 | Column oven | 1 set |
10 | Organic membrane | 1 box |
11 | Liquid micro syringe | 2 pieces |
12 | Solvent tray | 1 set |
13 | Starter Kit (Dual Pump System) | 1 set |
14 | Sand core filter | 1 set |
15 | RI differential detector | 1 set |
16 | Cyano column 7.5-10mm*250mm 5-10um | 1 piece |
17 | Silica column 7.5-10mm *500mm 5um | 1 piece |