Gel Index Tester (LTLS)
Brand KN
Product origin DALIAN
Delivery time 30 DAYS AFTER RECEIVING FULL PAYMENT
Supply capacity 30 sets/month
KN-5133 Gel Index Tester (LTLS) conforms to ASTM D5133 Standard Test Method for Low Temperature, Low Shear Rate, Viscosity/Temperature Dependence of Lubricating Oils Using a Temperature Scanning Technique. This test method covers the measurement of the apparent viscosity of engine oil at low temperatures and ASTM D7110 Standard Test Method for Determining the Viscosity-Temperature Relationship of Used and Soot-Containing Engine Oils at Low Temperature. This Test method covers how to measure the apparent viscosity of used and soot-containing engine oils at low temperature.
KN-5133 Gel Index Tester (LTLS)
Overview
KN-5133 Gel Index Tester (LTLS) conforms to ASTM D5133 Standard Test Method for Low Temperature, Low Shear Rate, Viscosity/Temperature Dependence of Lubricating Oils Using a Temperature Scanning Technique. This test method covers the measurement of the apparent viscosity of engine oil at low temperatures and ASTM D7110 Standard Test Method for Determining the Viscosity-Temperature Relationship of Used and Soot-Containing Engine Oils at Low Temperature. This Test method covers how to measure the apparent viscosity of used and soot-containing engine oils at low temperature.
Features
Metal bath cold well, no noise
Microcomputer temperature controller, PID adjustment, PT100 temperature sensor with high precision
One-button automatic lifting system, hydrometer automatic positioning
Unique test tube lock device, it is able to fix the test tube stable
Big touch screen operation
Dedicated software, be able to correct the viscosity and analysis the linear accuracy
Automatic calibration process, the calibration data will be shown in diagram
Multiple temperature correction, also can add the correction point freely
Automatic scan the viscosity and generate the gel curve. Will automatic analysis the gel index and temperature
Adopts linear curve cooling, cooling rate could be edited
Technical Parameters
Cooling mode: Semi-conductor analysis the linear accuracy
Temperature control mode: Digital display PID temperature controller
Temperature control range: Ambient~40±0.1℃
Measuring range: 0~40000mPa·s
Operation mode: Touch screen
Lifting mode: Automatic
Rated voltage: AC220V, 50Hz
Total power: Main host: 800W,
Low temperature bath:1200W
Dimension: Main host: 400*250*700mm,
Low temperature bath: 430*540*730mm
Net weight: Main host: 32kg,
Low temperature bath: 45kg