AutomaticPotentiometric Titrator
Brand KN
Product origin DALIAN
Delivery time 30 DAYS AFTER RECEIVING FULL PAYMENT
Supply capacity 30 sets/month
KN-titrate Automated Potentiometric Titrator is used for determination of Total Acid Number (TAN), Total Base Number (TBN), Mercaptan Sulfur and chlorine content of petroleum products, lubricants and transformer insulating oils. Titration is the fundamental chemical analysis procedure whereby the concentration of a chemical substance in solution is determined by reacting it with a measured amount of another chemical. The Auto titrator performs this analysis using a motor driven dispenser, stirred reaction vessel and electrodes which sense the completion of reaction by measuring the potential difference between two electrodes. Automatic Titration increases accuracy, repeatability and reproducibility as well as minimizing errors in calculation and documentation
KN-titrate-A Automated Potentiometric Titrator
Overview
KN-titrate-A Automated Potentiometric Titrator is used for determination of Total Acid Number (TAN), Total Base Number (TBN), Mercaptan Sulfur and chlorine content of petroleum products, lubricants and transformer insulating oils. Titration is the fundamental chemical analysis procedure whereby the concentration of a chemical substance in solution is determined by reacting it with a measured amount of another chemical. The Auto titrator performs this analysis using a motor driven dispenser, stirred reaction vessel and electrodes which sense the completion of reaction by measuring the potential difference between two electrodes. Automatic Titration increases accuracy, repeatability and reproducibility as well as minimizing errors in calculation and documentation.
Application standards
1. ASTM D664 Standard Test Method for Acid Number of Petroleum Products by Potentiometric Titration
2. ASTM D974 Standard Test Method for Acid and Base Number by Color-Indicator Titration
3. ASTM D2896 Standard Test Method for Base Number of Petroleum Products by Potentiometric Perchloric Acid Titration
4. ASTM D4929 Standard Test Methods for Determination of Organic Chloride Content in Crude Oil, test method A
5. ASTM D3227 Standard Test Method for (Thiol Mercaptan) Sulfur in Gasoline, Kerosine, Aviation Turbine, and Distillate Fuels (Potentiometric Method)
6. ASTM D4739 Standard Test Method for Base Number Determination by Potentiometric Hydrochloric Acid Titration
7. UOP163 Hydrogen Sulfide and Mercaptan Sulfur in Liquid Hydrocarbons by Potentiometric Titration
8. ASTM D94 Standard Test Methods for Saponification Number of Petroleum Products
9. ASTM 1159 Standard Test Method for Bromine Number of Petroleum Distillates and Commercial Alphatic Olefins by Electrometric Titration
Features
1. Unique built-in dosing unit to avoid the harmless chemical leak
2. Can do multiple kinds of titration, Acid-base or aqueous titration, Redox titration, Complexometric titration or EDTA titration, Blank titration, Silver Assay titrations, Non-aqueous titration, Argentometric or Precipitation titration,Back titration
3. Multiple self-checking function to avoid mis-operating
4. Flexible application edit functions, operator can store the dedicated titration mode to the test and adopt this mode next time by one click
5. RS232/USB port, with networked CAN but communication functions.
6. Very easy to use - intuitive keypad and function guide display
7. Programmable – TAN,TBN software built-in
8. Results expressed in mg KOH/g
9. Connects to external pc keyboard for easy text and sample information data entry
10. Connects to different types printers, pc and balances
11. Data Logger – automatic data storage of last 55 analysis results
12. Hamilton electrode ,model number: 238060 FLUSHTRODE made in Swiss
Technical parameters
MV Measuring range: -2000.0MV~+2000.0MV, ±0.1MV | Temperature measuring: -5~~120℃, |
PH measuring range: -20.000PH~+20.000PH | MV test:Resolution 0.1mV, accuracy 0.1mV±0.03% |
PH resolution: 0.001PH, Accuracy: ±0.003PH | Temperature measuring precision: ±0.1℃ |
Operation: PC controlled | Burette rehydration time: 16s (100% filling rate) |
Sampler: standard equipped with single titration platform Optional 16-stations 100mL autosampler, 12-stations 250mL autosampler, 18-stations50mL autosampler Stirring way:magneticstir,optional up stirring Burette resolution: 1/1500000 Titration type:Potentiometric titration | Electrode connector type:mV/pH measuring electrode interface, reference electrode interface, PT1000 temperature electrode interface Burette refill time: 16S Compatible with burette specifications: 1mL 5mL 10mL 25mL |