ASTM D92 Automatic Cleveland Open Cup Flash Point Tester
Flash point can indicate the possible presence of highly volatile and flammable materials in a relatively nonvolatile or nonflammable material. For example, an abnormally low flash point on a test specimen of engine oil can indicate gasoline contamination
Send Email Details -
Manual Pensky-Martens Closed Cup Flash Point Tester
The flash point temperature is one measure of the tendency of the test specimen to form a flammable mixture with air under controlled laboratory conditions. It is only one of a number of properties which must be considered in assessing the overall flammability hazard of a material
Send Email Details -
Automaitc Pensky-Martens Closed Cup Flash Point Tester
The flash point temperature is one measure of the tendency of the test specimen to form a flammable mixture with air under controlled laboratory conditions. It is only one of a number of properties which must be considered in assessing the overall flammability hazard of a material
Send Email Details -
ASTM D56 Tag Closed Cup Flash Point Tester
this apparatus conforms to ASTM D56 Standard Test Method for Flash Point by Tag Closed Cup Tester, it is used for flash point determinations of liquids with a viscosity of below 5.5 centistokes (cSt) at 104℉ (40℃) or below 9.5cSt at 77℉ (25℃),
Send Email Details -
IP170 Abel Flash Point Tester
This International Standard specifies a method for the determination of the closed cup flash point of petroleum products and other liquids having flash points between -30℃ and 70℃ inclusive.
Send Email Details -
ISO 13736 Automatic Abel Closed Cup Flash Point Tester
KN-170Z Automatic Abel Closed Cup Flash Point Tester conforms to IP170 Petroleum products and other liquids -- Determination of flash point -- Abel closed cup method and ISO 13736 Petroleum Products and Other Liquids - Determination of Flash Point - Abel Closed Cup Method and IP170 Determination of flash point - Abel closed-cup method. This International Standard specifies a method for the determination of the closed cup flash point of petroleum products and other liquids having flash points between -30℃ and 70℃ inclusive. However, the precision given for the method is only valid for flash points in the range -5℃ to 66.5℃. This standard is not acceptable to water borne paints which may however be tested using ISO 3679
Send Email Details -
KN-NIR Near Infrared Spectrometer
KN-NIR Near Infrared Spectrometer adopts advanced MEMS Fourier transform technology. Optional spectral range of the instrument (1300nm~2600nm, 1150~1700nm, 1250~2100nm) meets the needs in testing multiple indicators and research. High signal to noise ratio is possible to analyze the parameters of low content of the sample. Built in wavelength calibration to ensure smaller difference between stations difference and better long-term stability. The tester equipped with a temperature control device, which can improve the data stability.
Send Email Details