KN-NIR Near Infrared Spectrometer
Brand KN
Product origin Dalian
Delivery time 30 days after receiving full payment
Supply capacity 30 sets / month
KN-NIR Near Infrared Spectrometer adopts advanced MEMS Fourier transform technology. Optional spectral range of the instrument (1300nm~2600nm, 1150~1700nm, 1250~2100nm) meets the needs in testing multiple indicators and research. High signal to noise ratio is possible to analyze the parameters of low content of the sample. Built in wavelength calibration to ensure smaller difference between stations difference and better long-term stability. The tester equipped with a temperature control device, which can improve the data stability.
KN-NIR Near Infrared Spectrometer
Overview
KN-NIR Near Infrared Spectrometer adopts advanced MEMS Fourier transform technology. Optional spectral range of the instrument (1300nm~2600nm, 1150~1700nm, 1250~2100nm) meets the needs in testing multiple indicators and research. High signal to noise ratio is possible to analyze the parameters of low content of the sample. Built in wavelength calibration to ensure smaller difference between stations difference and better long-term stability. The tester equipped with a temperature control device, which can improve the data stability.
Features
1. 1300~2600nm, 1150~1700nm, 1250~2100nm optional multi-spectral range
2. Miniaturized design
3. Only take about 60~180s to finish the test
4. Industrial-grade design, the whole tester has no mechanical moving parts, and remains stable in harsh environments
5. Built-in industrial grade PC
6. Adopts MLR and PLS mainstream metrology processing algorithms. It overcomes the non-linear problems of traditional methods. Used for process control, research and development
7. Designed with transmitted light path, equipped with temperature control device to ensure the stability of the sample spectrum information.
Technical parameters
Sample type | Sample Name | Index |
Oil | Gasoline | Olefins, Aromatics (Benzene, toluene, xylene, etc.) Distillation range, Research octane number , motor octane number, etc. |
Diesel | Cetane number, distillation range, density, flash point, etc. | |
Aviation Kerosene | Distillation range, flash point, acidity, freezing point, density, etc. | |
Polymer materials | Polyester and polyether polyols, ethylene glycol | Hydroxyl value, iodine value, moisture, etc. |
Other liquid samples | Beer, drinks, etc |
Technical parameters
Detector | InGaAs | Lamp Power | 5W | SNR | 3000:1 (1800nm) |
Sample Temperature | 25±2℃ | Communication Port | USB2.0 | Ambient Humidity | 5%~95% |
Ambient Temperature | 5℃~40℃ | Resolution | 8nm (1550nm) | Dimension (L*W*H) | 473*386*199mm |
Power Supply | DC12V/8A | Operation System | Win7/Win10 | Weight | 5kg |
Wavelength Range | 1150nm~1700nm/1250nm~2100nm/1300nm~2600nm (Optional) |