KN-7536 Apparatus for Chlorine in Aromatics conforms to ASTM D7536 Standard Test Method for Chlorine in Aromatics by Monochromatic Wavelength Dispersive X-ray Fluorescence Spectrometry. This test method provides for the precise measurement of the chlorine content of aromatics with minimal sample preparation and analyst involvement. The typical time for each analysis is five or ten minutes. Knowledge of the chlorine content of aromatics is important for process control as well as the prediction and control of operational problems such as unit corrosion and catalyst poisoning, and in the blending of products to commodity specifications. Various federal, state, and local agencies regulate the chlorine content of some petroleum products, including aromatics. Unbiased and precise determination of chlorine in aromatics is critical to compliance with regulatory standards.

Apparatus for Chlorine in Aromatics

KN-7536 Apparatus for Chlorine in Aromatics

Overview

  KN-7536 Apparatus for Chlorine in Aromatics conforms to ASTM D7536 Standard Test Method for Chlorine in Aromatics by Monochromatic Wavelength Dispersive X-ray Fluorescence Spectrometry. This test method provides for the precise measurement of the chlorine content of aromatics with minimal sample preparation and analyst involvement. The typical time for each analysis is five or ten minutes. Knowledge of the chlorine content of aromatics is important for process control as well as the prediction and control of operational problems such as unit corrosion and catalyst poisoning, and in the blending of products to commodity specifications. Various federal, state, and local agencies regulate the chlorine content of some petroleum products, including aromatics. Unbiased and precise determination of chlorine in aromatics is critical to compliance with regulatory standards.


Features

1.         Johansson-type DCG system, advanced design of beam path

2.         After calibration before ex-factory, will never have optical path displacement

3.         No need conversion gasses, vacuum requirements or self-aeration system

4.         No need to establish working curves frequently

5.         Intuitive touch screen operation


Technical parameters

1.         Limit of detection 0.2ppm (300s)

2.         Range: 0.5ppm~5%

3.         Measuring time: 60~300s (selectable)

4.         Standard deviation: Sn-1≤0.5ppm (5ppm), 2.5ppm (50ppm)

5.         I/O ports: USB

6.         Rated voltage: 220V±10%, 5A/110V±10%, 5A

7.         Dimension: 614*444*375mm